TERMOSYSTEM EPS G
Waterproof thermal insulator
|
 |
TERMOSYSTEM EPS G® Waterproof thermal insulator
Waterproof insulating system suitable for both civil and industrial coverings. The system versatility allows to obtain various solutions with easy laying procedures. It is produced by coupling a waterproof bituminous membrane, either self-protected or non self-protected, with a choice of reinforcements displaying cold flexibility characteristics, and various types of different thickness insulating material.
The TERMOSYSTEM EPS G® waterproof thermal insulator is a composite system made up of a bituminous membrane coupled with an insulating panel in sintered expanded polystyrene with added graphite, complying with EN 13163 standards and offering fire retardant properties (Euroclass“E”).
 |
ADVANTAGES:
• Easy and versatile to install • Large surfaces covered in little time, great value for money • Maintenance/modification operations carried out on the surface |  |
 |
COMPOSITION:
TERMOSYSTEM EPS G® comes in the following versions: • Rolls where the insulating material has staves 50 mm wide and 1 m high, with selvage on one side. The rolls are manufactured in a range of thickness up to 70 mm. • Customized panels according to client’s requirements with overlapping selvage on both the short and long side. • Precut panels for vaulted and shed style roofs, with overlapping selvage on both the short and long side. • Sloping panels for flat sloping roofs.
1 Insulating material 2 Polymeric bitumen 3 Glass fiber reinforcement or T.N.T. - polyester 4 Polymeric bitumen with ceramic coated granules |
Technical characteristics
|
Technical characteristics of the elastoplastomeric polymer bitumen compound before coupling
|
|
Description
|
U.M.
|
Smooth glass fiber
|
Smooth polyester
|
Polyester Ministry Authorization
|
Standard
|
|
Shape stability in response to heat |
°C |
110 |
110 |
110 |
EN 1110 |
|
Cold flexibility |
°C |
-5 |
-5 |
-5 |
UNI EN 1109 |
|
Ultimate tensile strength – in the longitudinal direction |
% |
/ |
≤-0,25 |
≤+0,25 |
EN 1107-A |
|
Ultimate tensile strength – in the transverse direction |
% |
/ |
≤-0,25 |
≤+0,25 |
EN 1107-A |
|
Impermeability to water |
KPa |
≥60 |
≥60 |
≥60 |
UNI EN 1928 |
|
Ultimate tensile strength – in the longitudinal direction |
N50/mm |
310 |
530 |
530 |
UNI EN 12311-1 |
|
Ultimate tensile strength – in the transverse direction |
N50/mm |
205 |
400 |
400 |
UNI EN 12311-1 |
|
Elongation at break - longitudinal |
% |
2 |
35 |
35 |
UNI EN 12311-1 |
|
Elongation at break - longitudinal |
% |
2 |
40 |
40 |
UNI EN 12311-1 |
|
Tear resistance - longitudinal |
N |
70 |
120 |
120 |
UNI EN 12310-1 |
|
Tear resistance - transversal |
N |
80 |
120 |
120 |
UNI EN 12310-1 |
|
Resistance to static punching |
Kg |
5 |
10 |
10 |
UNI EN 12730 |
Technical characteristics of sintered EPS-G expanded polystyrene before coupling
|
|
Description
|
Standard EN 13163
|
U.M.
|
EPS 50
|
EPS 100
|
Standard
|
|
Dimensional stability in specified temperature and humidity conditions |
DS(N) |
% |
±5 |
±5 |
EN 1603 |
|
Flexural strength |
BS |
KPa |
≥90 |
≥150 |
EN 12089 |
|
Compressive strength at 10% deformation |
CS(10) |
KPa |
≥50 |
≥100 |
EN 826 |
|
Resistance factor to water vapour diffusion |
|
μ |
20-40 |
30-70 |
EN 12086 |
|
Thermal conductivity (λ) |
|
w/mk |
0.034 |
0,032 |
EN 13163 |
|
European fire reaction class |
Class |
|
E |
E |
EN 13501/1 |
|
|
|
|